InfoPanel.getAD_Window_ID doesn't use ZoomCondition

Description

Hi,

The getADWindow_ID method try to retrieves the default window on AD_Table.AD_Window_ID / PO_Window_ID.
Thus, ZoomCondition are not used.

But I don't see how we can use them :-/

Any idea ?

Regards,

Nicolas

Environment

None

Activity

Show:

Carlos Ruiz November 15, 2017 at 8:59 AM

It's working fine in test.idempiere.org

Nicolas Micoud November 15, 2017 at 8:25 AM
Edited

Duplicate Business Partner Window
Remove access to Business Partner (original one)
Give access to Business Partner (new one)
Login with the role, open InfoWindow BP and try to zoom. It fails
(just done in test.idempiere.org through GardenUser)

Log says :
09:23:53.442===========> GridWindowVO.create: No Window - AD_Window_ID=123, AD_Role_ID=MRole[103,GardenWorld User,UserLevel= O,AD_Client_ID IN(0,11),AD_Org_ID IN(0,11,50000,50001,50007)] - SELECT Name,Description,Help,WindowType, AD_Color_ID,AD_Image_ID,WinHeight,WinWidth, IsSOTrx, AD_Window_UU FROM AD_Window w WHERE w.AD_Window_ID=? AND w.IsActive='Y' [637]
09:23:53.635===========> CLogger.saveError: AccessTableNoView - (Not found) [637]

Nicolas

Carlos Ruiz November 15, 2017 at 8:20 AM

Hi , any test case failing?

I tried setting a different zoom in table and it worked.

Regards,

Carlos Ruiz

Cannot Reproduce

Details

Assignee

Reporter

Priority

Created November 10, 2017 at 9:12 AM
Updated January 1, 2018 at 12:12 PM
Resolved November 15, 2017 at 9:18 AM